Home About Us Distributor Locator New Products Contact Us  
 
 
Large Vacuum Pumps
Dual Base Pumps
Triple Base Pumps
Quad Base Pumps

Triple Base Vacuum Pumps: Piloted Variable and Solenoid Variable Capacity Options

E, L, M, ML Series: Sizes 200 to 900
X Series: Size 320 to 1440

Port Connections
Code Function Size
1 Air Supply - Main 3/4
2 Vacuum - Main 2
2A Vacuum - Alternate 1/8
3 Exhaust 3/4
4 Pilot Signal - Air Control 1/8
5 Pilot Signal - Quick Release 1/8

Weight: add 1.6 lbs. (0.72kg) to basic weight

Pump Size "Z"
200-300 0.76 (19.3)
400-600 1.47 (37.3)
700-800 2.18 (55.3)


PV = Piloted Variable Capacity:
Includes three air piloted supply valves and non-return valves for independent control of each station via separate remote pilot signals with a constant air supply to the pump base inlet port. With this option, one pump assembly can have up to 6 different capacities that can be selected to exactly suit the system requirements at any given time. A quick release valve (RP, RT) should also be specified. When RT is used, the Pilot line is connected at the time of installation to suit the application.

SV = Piloted Variable Capacity: Includes three solenoid supply valves and non-return valves for independent control of each station via separate remote pilot signals with a constant air supply to the pump bas inlet port. With this option, one pump assembly can have up to 6 different capacities that can be selected to exactly suit the system requirements at any given time. A quick release valve (RP, RT) should also be specified. When RT is used, the Pilot line is connected at the time of installation to suit the application.