Home About Us Distributor Locator New Products Contact Us  
 
 
Single Stage Pumps
V-Series Pumps
EV-Style Vacuum Pumps
SM Pumps
ER Pumps
Vacuum Bar Pumps
Variable Displacement Pumps
How to Order

VDS Pumps: Variable Displacement


VDS vacuum pumps can provide over 20" Hg (68 kPa) and their straight through non-clog design is ideal for very dusty and dirty applications such as bag filling or handling ceramics or masonry products. The square body and two mounting holes makes the VDS pump easy to attach to any flat surface. An ST Straight Thru silencer will not accumulate debris and will pass it out with the exhaust air. For less critical applications where cost is more of an issue, a conventional AA silencer may be used.



Operation

Loosen the jam nut and turn the diffuser nozzle clockwise, by hand, until it contacts the inlet nozzle. With the work piece against the suction cup or holding fixture, supply regulated compressed air to the side air supply port and gradually rotate the diffuser nozzle to adjust the annular gap between the two nozzles until the desired vacuum level or vacuum flow is achieved. To minimize air consumption, use the lowest pressure air supply that will yield the desired results. Turning the diffuser too far open will suddenly cause a decrease in performance and this point will vary depending on the operating air pressure. Ingested debris passes directly from end-to-end through the pump bore without any turns and without passing through the annular venturi created by the inlet and diffuser nozzles, so there is no opportunity for clogging as long as the pump bore is large enough to pass the largest debris particle. As the pump bore size is increased, it can also generate more vacuum flow to overcome porosity and leakage.
Model Bore I.D. Air Supply Vacuum Exhaust A B C D E F G H S
VDS 150 0.150 (3.8) G 1/8 NPSF 1/4" OR G1/4 1/4" OR G1/4 1.38 (35) .86 (21.8) 1.25 (31.8) 3.81 (96.7) 1.02 (25.9) .84 (21.3) .74 (18.8) .22 (5.5) 2.26 (57.4)
VDS 200 0.200 (5.1) G 1/8 NPSF 1/4" OR G1/4 1/4" OR G1/4 1.38 (35) .86 (21.8) 1.25 (31.8) 3.81 (96.7) 1.02 (25.9) .84 (21.3) .74 (18.8) .22 (5.5) 2.26 (57.4)
VDS 250 0.250 (6.3) G 1/8 NPSF 1/4" OR G1/4 1/4" OR G1/4 1.38 (35) .86 (21.8) 1.25 (31.8) 3.81 (96.7) 1.02 (25.9) .84 (21.3) .74 (18.8) .22 (5.5) 2.26 (57.4)
VDS 375 0.375 (9.5) G 3/8 NPSF 3/8 NPSF 1/2" OR G1/2 1.72 (43.7) 1.50 (38.1) 1.75 (44.5) 5.99 (152) 1.32 (33.5) 1.35 (34.3) .98 (24.9) .26 (6.6) 4.78 (121.4)
MODEL MAX VACUUM
FLOW SCFM
AIR CONSUMPTION vs. VACUUM LEVEL(inHg)
@ 80 PSI
    0 5 10 15 20 25
VDS-150 3.2 0 1.3 1.7 2.4 3.2 4.5
VDS-200 6.0 0 2.4 3.7 4.7 6.0 6.8
VDS-250 10.0 0 4.0 6.0 8.3 9.7 12.0
VDS-375 30.0 0 6.2 11.5 17 21 29.0